CSC Scientific DuNouy Precision and Interfacial Tensiometers. Provides rapid surface tension measurements—15 to 30 secinds. $7, – $8, The force maximum is determined with a modern tensiometer (K, K20) with the help of an With the Du Noüy ring method, a correction must be made to the . The CSC-Dunouy Tensiometer is a precision instrument used for measuring both The CSC-Dunouy Tensiometers (Fig.1 and 2) use a fine torsion wire for.

Author: Kazrajora Tygokree
Country: Montserrat
Language: English (Spanish)
Genre: Love
Published (Last): 16 December 2018
Pages: 63
PDF File Size: 7.22 Mb
ePub File Size: 12.39 Mb
ISBN: 479-1-81530-645-7
Downloads: 42044
Price: Free* [*Free Regsitration Required]
Uploader: Dogami

The force required to raise the ring from the liquid’s surface is measured and related to the liquid’s surface tension.

The measurement is performed with a force tensiometerwhich typically uses an electrobalance to measure the excess force caused by the liquid being pulled up and automatically calculates and displays the surface tension corresponding to the force. From Wikipedia, the free encyclopedia.

To measure the surface tension between a liquid and the air, the Tensiometer duNouy ring is placed below the surface of the liquid. Earlier, torsion wire balances were commonly used. Surface Tensiometer Du nouy ring tensiometer.

The force needed to break through the surface of the higher density liquid is recorded as interfacial surface tension. Commons category link is on Wikidata. Your browser does not support the video tag.

  HANDY THE SIGMOID CURVE PDF

Copyright Beijing United Test Co. There are applications where the surface tension at the boundary of two liquids needs to tehsiometer measured. This is called interfacial surface tension. How can we help you?

Du Noüy ring method

The force needed to break the boundary going from the floating liquid to the greater density liquid is measured by pushing the ring down through the boundary. Item Quantity Frame 1 set Platinum ring R9. The most common correction factors include those by Zuidema and Waters for liquids with low interfacial tensionHuh and Mason which covers a wider range than Zuidema-Waterstensoometer Harkins and Jordan more precise than Huh-Mason while still covering the most widely used liquids.

Documents Manual, packing list, certificate. The Tensiometer for this test needs to pull the ring up through the boundary between the lower, higher density liquid, and the liquid that is floating above.

The method involves slowly lifting a ring, often made of platinum, from the surface of a liquid. By using this site, you agree to the Terms of Use and Privacy Policy. Measuring instruments Laboratory rensiometer. English software For TEN Views Read Edit View history.

  HAIDINGER FRINGES PDF

This page was last edited on 3 Octoberat The method involves slowly lifting a ring, often made of platinum, from the surface of a liquid. Nnouy Nouy ring method: Platinum ring perimeter length.

Du Noüy ring method

The du Nouy ring method is one technique by which the surface tension of a liquid can be measured. The force needed for the ring to break the surface overcome the surface tension is determined.

Fundamentals of Interface and Colloid Science: This test is performed by pulling the ring upward through the surface of the liquid. In other nouu Wikimedia Commons. Retrieved from ” https: The Journal of General Physiology. The maximum tejsiometer is used for the calculations, and empirically determined correction factors are required to remove the effect caused by the finite diameter of the ring:.